Accessibility

Accessibility Checker Help

Screen selected door, route and ramp dimensions against a deliberately limited England or federal ADA context.

How to use the Accessibility Checker

Define the complete route being screened, the drawing revision and the selected England or US federal source context; collect clear opening, corridor and ramp dimensions from coordinated information.

The workspace starts blank. Load example temporarily fills the controls with demonstration data; reload or use the tool’s New or reset action, where provided, before entering live information.

  • Choose Jurisdiction / source and Units, then enter a Route reference and Evidence reference.
  • Enter door clear width and the applicable approach, corridor width and passing context, plus ramp rise, going and width where relevant.
  • Review the dimensional trace and margin for each item rather than treating the overall screen as one pass or fail.
  • Set each non-dimensional review item to Confirmed, Action required, Not applicable or Not reviewed and add an evidence reference.

Worked examples

These examples explain the set-up, expected output and review needed without changing the tool workspace.

Entrance-to-WC route screen

Set-up
Record the entrance door clear opening, corridor width and the ramp or level approach against a named drawing revision.
Result
The screen separates measured dimensional findings from items that still require evidence or whole-route review.
Review
Continue through controls, turning space, fixtures, signage, lighting, gradients and local requirements not represented by the inputs.

Right-angle door approach

Set-up
Choose the approach condition that matches the plan and enter the measured clear opening rather than the nominal door-leaf size.
Result
The tool shows the selected threshold context and dimensional margin.
Review
Confirm maneuvering space, ironmongery, opening force and obstructions using the applicable project source.

Suggested workflow

Place the tool in a controlled project or practice process rather than treating its output as an isolated verdict.

  • Trace one complete user route and identify each dimensional and non-dimensional decision point.
  • Run the limited screen from coordinated measurements and assign unresolved evidence.
  • Close the actions through a project-specific accessibility review using the applicable adopted requirements.

Check before saving or issuing

  • Door input is clear opening width, not structural opening or leaf designation.
  • The selected approach and corridor context match the actual plan geometry.
  • Every Not reviewed or Action required item has an owner or evidence route outside the tool.

Common problems

  • A door unexpectedly fails: confirm the measured clear opening and selected approach condition.
  • Ramp result is misleading: check that rise and going use the same unit system and cover the full sloping run.
  • All dimensions pass but the route is not accessible: review the omitted spatial, sensory, operational and local-code requirements.

Output

A scoped dimensional screen and accessibility action record.

Professional boundary

It is not a complete accessibility assessment; scoping, maneuvering, fixtures, exceptions, local adoption and the whole route remain outside the result.